A PHP Error was encountered

Severity: Warning

Message: fopen(/tmp/ci_sessione9a53af38d282b9b5e91208f56e9389ec569082c): failed to open stream: Disk quota exceeded

Filename: drivers/Session_files_driver.php

Line Number: 176

Backtrace:

File: /home/hitechzo/public_html/laboton.com/application/controllers/Main.php
Line: 9
Function: __construct

File: /home/hitechzo/public_html/laboton.com/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /tmp)

Filename: Session/Session.php

Line Number: 143

Backtrace:

File: /home/hitechzo/public_html/laboton.com/application/controllers/Main.php
Line: 9
Function: __construct

File: /home/hitechzo/public_html/laboton.com/index.php
Line: 315
Function: require_once

Laboton. laboton
Generate Catalog For:
Mobile X-ray machine KMX-B102
KMX-B102

Mobile X-ray machine KMX-B102

www.laboton.com | info@laboton.com

Mobile X-ray machine KMX-B102

Mobile X-ray machine KMX-B102 is an advanced x-ray imaging modality designed for better mobility and manageability during intra-hospital transit. System is equipped with 50 pre-set exposure programs with automatic back-up memory and multiple protection functions for safer use. Automatic self-test setting and alarming reduces need for maintenance. Proximal as well as remote accessibility controllers make it more versatile to use.

Specifications :
Inverter Frequency 50 kHz
Tube Voltage 40 kV – 100 kV (interval 1 kV)
Operational Access Wired/Wireless Control
Current 1.0–125 mAs (43 steps)
Power Rating 3.5 kVA
Internal Resistance ≤ 1 Ω
Exposure Parameters
VoltageCurrentRadiographic Density
40 kV - 49 kV63 mA1 mAs - 125 mAs
50 kV - 59 kV55 mA1 mAs - 110 mAs
60 kV - 69 kV45 mA1 mAs - 90 mAs
70 kV - 79 kV40 mA1 mAs - 80 mAs
80 kV - 89 kV36 mA1 mAs - 71 mAs
90 kV - 99 kV32 mA1 mAs - 63 mAs
100 kV - 110 kV20 mA1 mAs - 40 mAs
Power Supply Voltage : 220 V ±10% Frequency : 50Hz
Dimensions 1220 x 900 x 1460 mm
Weight 207 Kgs
Features :
  •   High frequency X-ray generation
  •   High quality X-ray monolight technology
  •   Exposure current: 1.0-180mAs (46 steps)
  •   50 built-in exposure control programs
  •   Accurate X-ray penetration
  •   Flexible and easy source orientation
  •   Symmetrical collimator
  •   Mobile table (optional)
APPLICATIONS :

Used throughout the hospital from in-patient, to NICU, operating room, and emergency room as well as polyclinics to perform projection radiography readily on bedbound or critical patients for convenience.